The Lynx Smart BMS is a dedicated Battery Management System for Victron Lithium Smart Batteries. There are multiple BMS-es available for our Smart Lithium series of batteries, and the Lynx Smart is the most feature rich and complete option. It is available in two versions: 500A (with M8 busbar connections) and 1000A (with M10 busbar connections).
The Lynx Smart BMS is part of the modular Lynx Distribution system.
POWER
Battery Voltage Range- 9 -60VDC
Maximum Input Voltage- 75VDC
Supported System Voltages- 12V, 24V, 48V
Reverse Polarity Protection- No
Main Safety Contactor Continuous Current Rating-
Main Safety Contactor Peak Current Rating-
Power Consumption OFF Mode- 0.3 mA for all system voltages
Power Consumption in Standby Mode- Approximately 0.6W (50 mA at 12V)
Power Consumption in ON Mode-
Minimum Load Resistance For Pre-Charging- 10Ω and above for 12V systems, 20Ω and above for 24V and 48V systems
Aux Output Maximum Current Rating- 1.1A continuous, protected by resettable fuse
Allow-to-Charge Port Maximum Current Rating- 0.5A at 60VDC, Protected by resettable fuse
Allow-to-Discharge Port Maximum Current Rating- 0.5A at 60VDC, Protected by resettable fuse
Alarm Relay (SPDT) Maximum Current Rating- 2A at 60VDC
CONNECTIONS
Busbar-
VE.Can- RJ45
I/O- Removable multi-connector with screws terminals
Battery BTV Cables- Male and Female circular 3-pole connector with M8 screw ring Up to 20 Batteries can be connected in one system
Lynx Distributor Fuse Monitoring (Up to 4 modules)- RJ10 (cable ships with each Lynx Distributor)
PHYSICAL
Enclosure Material- ABS
Enclosure Dimensions (HxWxD)-
Unit Weight-
Busbar Material- Tinned Copper
Busbar Height- 0.31" x 1.18"
ENVIRONMENTAL
Operating Temperature Range- -40°F - 140°F
Storage Temperature Range- -40°F - 140°F
Humidity- Max. 95% (Non-Condensing)
Protection Class- IP22
STANDARDS
Safety- EN-IEC 63000:2018
EMC- EN-IEC 61000-6-3:2007 / A1:2011/ AC:2012
QMS- NEN-EN-ISO 9001:2015