The MAGNUM MS2012 Inverter/Charger is robust enough to meet the most demanding off-grid needs. The MS2012 meets all of the strict standards of UL458 for mobile use and UL1741 for renewable energy installs. The integrated 100A charger is Power Factor Corrected (PFC) which means that it uses 25-30% less energy from your generator. Free Shipping in the continental US!
Input Battery Voltage Range- 9 - 16.8VDC
AC Output Voltage Accuracy- 120 VAC ± 5%
Output Frequency And Accuracy- 60 Hz ± 0.1Hz
Total Harmonic Distortion (THD)- <5%
1 Msec Surge Current (amps AC)- 50
100 Msec Surge Current (amps AC)- 33
5 Sec Surge Power (real watts)- 3300
30 Sec Surge Power (real watts)- 3100
5 Minute Surge Power (real watts)- 2800
30 Minute Surge Power (real watts)- 2200
Output Power (continuous watts)- 2000
Maximum Continuous Input Current- 267 ADC
Inverter Efficiency (peak)- 90.6%
AC Relay Transfer Time (minimum)- 16 msecs
Power Consumption- Searching- <8 watts
Power Consumption- Inverting (no load)- 25 watts
Output Waveform- Pure Sine Wave
CHARGER SPECIFICATIONS
Continuous Output at 25°C- 100ADC
Charge Efficiency- 85%
Power Factor- >.95
Input Current For Continuous Rated Output- 15 AAC
GENERAL FEATURES AND CAPABILITIES
Transfer Relay Capability- 30 ACC max. each input (30AC total on MS2000 models, 60ACC total on all other models)
Five Stage Charging Capability- Bulk, Absorb, Float, Equalize (requires remote) and battery saver
Battery Temperature Compensation- Standard with available temp sensor connected (battery temp 0-50°C)
Internal Cooling- 0 to 120 cfm variable speed drive using dual 92mm brushless DC fans
Overcurrent Protection- Yes, with two overlapping circuits
Overtemperature Protection- Yes on transformer, MOSFETS, and battery
Corrosion Protection- Yes, PCB's conformal coated, powder coated chassis/top, and stainless steel fasteners
Branch-Rated Output Circuit Breakers- Optional on the MS2000 (15 or 20 amp breakers), MS2012 (15 or 20 amp breakers) or MS4048 (20 amp breakers)
Warranty- Three years parts and labor
PHYSICAL SPECIFICATIONS
Dimensions (LxWxH)- 13.75" x 12.85" x 8.0"
Mounting- Shelf or wall (vents not allowed to face downward unless ME-CB or MMP/MP is installed)
Unit Weight- 42lbs
Shipping Weight- 48lbs
Max Operating Altitude- 15,000"
Temperature (Operating/Non-Operating)- -20° - 60°C, -40° - 70°C
Operating Humidity- 0 - 95% RH non-condensing