The VE.Bus BMS V2 is a Battery Management System (BMS) designed to interface with and protect a single, or multiple Victron Lithium Battery Smart 12,8V & 25,6V (LiFePO4 or LFP) in systems that have Victron inverters or inverter/chargers with VE.Bus communication. It monitors and protects the batteries against over voltage and under voltage of any individual cell, and also over temperature or under temperature conditions.

Input Voltage Range- 9-70 VDC

Current Draw, Normal Operation- 10mA (Excluding Load Disconnect Current)

Current Draw, Low Cell Voltage- 2mA

GX Power Output- 1A

Aux-in Input- 1A

Load Disconnect Output- Normally High, Source current limit 1A, Sink Current 0A (Output Free Floating)

Charge Disconnect Output- Normally High, Source current limit 1A, Sink Current 0A (Output free floating)

Pre-Alarm Output- Normally free floating, High (Vbat) in case of alarm, max 1A, (Not short circuit proof)

Remote terminals- Usage Modes to turn the system on or off:

  1. ON when the L and H terminal are interconnected (switch or relay contact)
  2. ON when the L terminal is pulled to battery minus (V<3.5 V)
  3. ON when the H terminal is high (2.9V < VH<Vbat)
  4. OFF in all other conditions 

VE.Bus Communication Port- Two RJ45 sockets to connect to all VE.Bus products

Operating Temperature- -20 to +50°C , 0- 120°F

Humidity- Max 95% (non-condensing)

Protection Grade- IP20

Material and Colour- ABS, Matt Black

Weight- 120g

Dimensions (HxWxD)- 24mmx95mmx106mm

Standards- Safety Emission Immunity Automotive- EN60950, EN61000-6-3, EN55014-2, EN50498