Victron Energy UL Listed MultiPlus-II Inverter/ Chargers (3000VA)


The Victron Energy MultiPlus-II Inverter/Charger is an advanced and versatile device designed to provide power conversion, battery charging, and seamless energy management in both grid-connected and off-grid solar power systems.

Power Control & Power Assist- Yes

Transfer Switch- 50A

Maximum AC Input Current- 50A

INVERTER

DC Input Voltage Range- 

  • 12/3000/120-50 = 9.5 - 17V
  • 24/3000/70-50 = 19 - 33V
  • 48/3000/35-50 = 38 - 66V

Output Voltage- 120 VAC ± 2%

Output Frequency- 60 Hz ± 0.1%

Cont. Output Power at 25°C³- 3000VA

Cont. Output Power at 25°C- 2400W

Cont. Output Power at 40°C- 2200W

Cont. Output Power at 65°C- 1700W

Peak Power- 5500W

Maximum Efficiency- 

  • 12/3000/120-50 = 93%
  • 24/3000/70-50 = 94%
  • 48/3000/35-50 = 95%

Zero Load Power- 

  • 12/3000/120-50 = 13W
  • 24/3000/70-50 = 13W
  • 48/3000/35-50 = 11W

Zero Load Power In AES Mode-

  • 12/3000/120-50 = 9W
  • 24/3000/70-50 = 9W
  • 48/3000/35-50 = 7W

Zero Load Power In Search Mode- 

  • 12/3000/120-50 = 3W
  • 24/3000/70-50 = 3W
  • 48/3000/35-50 = 2W

CHARGER

AC Input Voltage- 90 -140VAC

AC Input Frequency- 45 - 65Hz

Charge Voltage 'Absorption'- 

  • 12/3000/120-50 = 14.4V
  • 24/3000/70-50 = 28.8V
  • 48/3000/35-50 = 57.6V

Charge Voltage 'Float'-

  • 12/3000/120-50 = 13.8V
  • 24/3000/70-50 = 27.6V
  • 48/3000/35-50 = 55.2V

Storage Mode- 

  • 12/3000/120-50 = 13.2V
  • 24/3000/70-50 = 26.4V
  • 48/3000/35-50 = 52.8V

Max. Battery Charge Current-

  • 12/3000/120-50 = 120A
  • 24/3000/70-50 = 70A
  • 48/3000/35-50 = 35A

Battery Temperature Sensor- Yes

GENERAL

Auxiliary Output- 32A

External AC Current Sensor (Optional)- 100A

Programmable Relay- Yes

Protection- a - g

VE.Bus Communication Port- For parallel, split phase and three phase operation, remote monitoring and system integration

General Purpose Com. Port- Yes 2x

Remote On/Off- Yes

Operating Temperature Range- -40°F - 140°F (Fan assisted cooling)

Humidity (Non-Condensing)- Max 95%

ENCLOSURE

Material & Color- Steel, Blue RAL 5012

Protection Category- IP22

Battery-Connection- M8 bolts

120V AC-Connection- 13mm² (6AWG)

Weight- 42lb

Dimensions (HxWxD)- 

  • 12/3000/120-50 = 22.8" x 10.9" x 5.8"
  • 24/3000/70-50 = 21.1" x  10.9" x 5.8"
  • 48/3000-35-50 = 22.5" x 10.9" x 5.8"

STANDARDS

Listings- 

  • 12/3000/120-50 = UL458
  • 24/3000/70-50 = UL458
  • 48/3000/35-50 = UL1741

Safety-  EN-IEC 60335-1, EN-IEC 60335-2-29, CSA 22.2 107.1-16

Emission, Immunity- EN 55014-1, EN 55014-2, EN-IEC 61000-3-2, EN-IEC 61000-3-3, IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3

 Uninterruptible Power Supply- Please consult the certificates on our website.

Anti-Islanding- Please consult the certificates on our website

1) Can be adjusted to 60Hz

2) Protection Key:

A) Output short circuit

B) Overload

C) Battery Voltage to high

D) Battery Voltage to low

E) Temperature to high

F) 230VAC on Inverter output

G) Input voltage ripple to high

3) Non-linear load, crest factor 3:!

4) Up to 25°C ambient

5)Program Relay which can be set for general alarm, DC under voltage or genset start/ stop function. 

AC Rating: 230V / 4A

DC Rating: 4A up to 35VDC and 1A up to 60VDC