Victron Energy Non-UL Listed Quattro Inverter/ Chargers (3000VA-15000VA)


Similar to the MultiPlus, the Quattro is also a combined inverter and charger. Additionally it can accept two AC inputs and automatically connect to the active source. Its many features include a true sine wave inverter, adaptive charging, hybrid PowerAssist technology plus multiple system integration features such as three or split phase operation and parallel operation.

Power Control & Power Assist- Yes

Integrated Transfer Switch- Yes

AC Inputs (2x)- 

  • Input Voltage Range- 90 - 140VAC
  • Input Frequency- 45 - 65Hz 
  • Power Factor- 1

Maximum Feed Through Current- 2x 50A

INVERTER

Input Voltage Range- 9.5V - 17V

Output Voltage- 120VAC ± 2%

Output Frequency- 60Hz ± 0.1%

Cont. Output Power at 25°C³- 3000VA

Cont. Output Power at 25°C- 2400W

Cont. Output Power at 40°C- 2200W

Cont. Output Power at 65°C- 1700W

Peak Power- 6000W

Maximum Efficiency- 94%

Zero Load Power- 25W

Zero Load Power In AES Mode- 20W

Zero Load Power In Search Mode- 12W

CHARGER

Charge Voltage 'Absorption' (V DC)- 57.6V

Charge Voltage 'Float' (V DC)- 55.2V

Storage Mode (V DC)- 52.8V

Charge Current House Battery (A)- 35A

Charge Current Starter Battery (A)- 4A (12V and 24V Models Only)

Battery Temperature Sensor- Yes

GENERAL

Auxiliary Output- 32A

Programmable Relay- 3x

Protection- a - g

VE.Bus Communication Port- For parallel, split phase and three phase operation, remote monitoring and system integration

General Purpose Com. Port- 2x

Remote On/Off- Yes

Operating Temperature- -40°C - 65°C

Humidity (Non-Condensing)- Max 95%

ENCLOSURE

Material & Color-  Aluminium Blue RAL 5012

Protection Category- IP21

Battery-Connection- Four M8 bolts (2 plus and 2 minus connections)

120 V AC-Connection- Screw Terminals 13mm² (6AWG)

Weight- 42lb

Dimensions (HxWxD)- 14.3" x 10.2" x 8.6"

STANDARDS

Safety- EN-IEC 60335-1, EN-IEC 60335-2-29, EN-IEC 62109-1

Emission, immunity- EN 55014-1, EN 55014-2, EN-IEC 61000-3-2, EN-IEC 61000-3-3, IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3

Road Vehicles- 12V and 24V models ECER10-S

Anti-Islanding- See our website

1) Can be adjusted to 60Hz, 120V 60Hz on request

2) Protection Key

A) Output short circuit

B) Overload

C) Battery voltage to high

D) Battery voltage to low

E) Temperature to high

F) 120VAC on inverter output

G) Input voltage ripple to high

3) Non-linear load, Crest factor 3:1

4) Up to 24°C ambient

5) Switches off when no external AC source available

6) Programmable relay that can a.o. be set for genera; alarm, DC under voltage or genset start/stop function

AC Rating- 230V / 4A

DC Rating- 4A up to 35VDC, 1A up to 60VDC

Power Control & Power Assist- Yes

Integrated Transfer Switch- Yes

AC Inputs (2x)-

  • Input Voltage Range- 90 - 140VAC
  • Input Frequency- 45 - 65HZ
  • Power Factor- 1

Maximum Feed Through- 2x 100A

INVERTER

Input Voltage Range- 

  • 12/5000/220-100/100 120V = 9.5V - 17V
  • 24/5000/120-100/100 120V =  19V - 33V
  • 48/5000/70-100/100 120V = 38V - 66V

Output Voltage- 120 VAC ± 2%

Output Frequency- 60Hz ± 0.1%

Cont. Output Power at 25°C³- 5000VA

Cont. Output Power at 25°C- 4000W

Cont. Output Power at 40°C- 37000W

Cont. Output Power at 65°C- 3000W

Peak Power- 10000W

Maximum Efficiency-

  • 12/5000/220-100/100 120V = 94%
  • 24/5000/120-100/100 120V = 94%
  • 48/5000/70-100/100 120V = 95%

Zero Load Power-

  • 12/5000/220-100/100 120V = 30W
  • 24/5000/120-100/100 120V = 30W
  • 48/5000/70-100/100 120V = 35W

Zero Load Power In AES Mode-

  • 12/5000/220-100/100 120V = 20W
  • 24/5000/120-100/100 120V = 25W
  • 48/5000/70-100/100 120V = 30W

Zero Load Power In Search Mode- 

  • 12/5000/220-100/100 120V = 10W
  • 24/5000/120-100/100 120V = 10W
  • 48/5000/70-100/100 120V = 15W

CHARGER

Charge Voltage 'Absorption' (V DC)-

  • 12/5000/220-100/100 120V = 14.4V
  • 24/5000/120-100/100 120V = 28.8V
  • 48/5000/70-100/100 120V = 57.6V

Charge Voltage 'Float' (V DC)- 

  • 12/5000/220-100/100 120V = 13.8V
  • 24/5000/120-100/100 120V = 27.6V
  • 48/5000/70-100/100 120V = 55.2V

Storage Mode (V DC)-

  • 12/5000/220-100/100 120V = 13.2V
  • 24/5000/120-100/100 120V = 26.4V
  • 48/5000/70-100/100 120V = 52.8V

Charge Current House Battery (A)-

  • 12/5000/220-100/100 120V = 200A
  • 24/5000/120-100/100 120V = 120A
  • 48/5000/70-100/100 120V = 70A

Charge Current Starter Battery (A)- 4A (12V and 24V models only)

Battery Temperature Sensor- Yes

GENERAL

Auxiliary Output- 50A

Programmable Relay- 3x

Protection- a - g

VE.Bus Communication Port- For parallel, split phase and three phase operation, remote monitoring and system integration

General Purpose Com. Port- 2x

Remote On/Off- Yes

Operating Temperature- -40°C - 65°C

Humidity (Non-Condensing)- Max 95%

ENCLOSURE

Material & Color-  Aluminium Blue RAL 5012

Protection Category- IP21

Battery-Connection- Four M8 bolts (2 plus and 2 minus connections)

120V AC-Connection- Bolts M6

Weight-

  • 12/5000/220-100/100 120V = 77lb
  • 24/5000/120-100/100 120V = 66lb
  • 48/5000/70-100/100 120V = 66lb

Dimensions (HxWxD)-

  • 12/5000/220-100/100 120V = 18.5" x 14.0" x 11.2"
  • 24/5000/120-100/100 120V = 17.5" x 13.0" x 9.6"
  • 48/5000/70-100/100 120V = 17.5" x 13.0" x 9.6"

STANDARDS

Safety- EN-IEC 60335-1, EN-IEC 60335-2-29, EN-IEC 62109-1

Emission, immunity- EN 55014-1, EN 55014-2, EN-IEC 61000-3-2, EN-IEC 61000-3-3, IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3

Road Vehicles- 12V and 24V models ECER10-S

Anti-Islanding- See our website

1) Can be adjusted to 60Hz, 120V 60Hz on request

2) Protection Key

A) Output short circuit

B) Overload

C) Battery voltage to high

D) Battery voltage to low

E) Temperature to high

F) 120VAC on inverter output

G) Input voltage ripple to high

3) Non-linear load, Crest factor 3:1

4) Up to 24°C ambient

5) Switches off when no external AC source available

6) Programmable relay that can a.o. be set for genera; alarm, DC under voltage or genset start/stop function

AC Rating- 230V / 4A

DC Rating- 4A up to 35VDC, 1A up to 60VDC

Power Control & Power Assist- Yes

Integrated Transfer Switch- Yes

AC Inputs (2x)- 

  • Input Voltage Range- 90 - 140VAC
  • Input Frequency- 45 - 65Hz 
  • Power Factor- 1

Maximum Feed Through Current- 2x 100A

INVERTER

Input Voltage Range- 38V - 66V

Output Voltage- 120VAC ± 2%

Output Frequency- 60Hz ± 0.1%

Cont. Output Power at 25°C³- 10000VA

Cont. Output Power at 25°C- 8000W

Cont. Output Power at 40°C- 6500W

Cont. Output Power at 65°C- 4500W

Peak Power- 20000W

Zero Load Power- 60W

Zero Load Power In AES Mode- 40W

Zero Load Power In Search Mode- 15W

CHARGER

Charge Voltage 'Absorption' (V DV)- 57.6V

Charge Voltage 'Float' (V DC)- 55.2V

Storage Mode (V DC)- 52.8V

Charge Current House Battery (A)- 140A

Charge Current Starter Battery (A)- 4A (12V and 24V models only)

Battery Temperature Sensor- Yes

GENERAL

Auxiliary Output- 50A

Programmable Relay- 3x

Protection- a - g

VE.Bus Communication Port- For parallel, split phase and three phase operation, remote monitoring and system integration

General Purpose Com. Port- 2x

Remote On/Off- Yes

Operating Temperature- -40°C - 65°C

Humidity (Non-Condensing)- Max 95%

ENCLOSURE

Material & Color-  Aluminium Blue RAL 5012

Protection Category- IP21

Battery-Connection- Four M8 bolts (2 plus and 2 minus connections)

120V AC-Connection- Bolts M6

Weight- 128lb

Dimensions (HxWxD)- 22.6" x 19.2" x 13.6"

STANDARDS

Safety- EN-IEC 60335-1, EN-IEC 60335-2-29, EN-IEC 62109-1

Emission, immunity- EN 55014-1, EN 55014-2, EN-IEC 61000-3-2, EN-IEC 61000-3-3, IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3

Road Vehicles- 12V and 24V models ECER10-S

Anti-Islanding- See our website

1) Can be adjusted to 60Hz, 120V 60Hz on request

2) Protection Key

A) Output short circuit

B) Overload

C) Battery voltage to high

D) Battery voltage to low

E) Temperature to high

F) 120VAC on inverter output

G) Input voltage ripple to high

3) Non-linear load, Crest factor 3:1

4) Up to 24°C ambient

5) Switches off when no external AC source available

6) Programmable relay that can a.o. be set for genera; alarm, DC under voltage or genset start/stop function

AC Rating- 230V / 4A

DC Rating- 4A up to 35VDC, 1A up to 60VDC

 Power Control & Power Assist- Yes

Integrated Transfer Switch- Yes

AC Inputs (2x)-

  • Input Voltage Range- 187-265VAC
  • Input Frequency- 45 - 65Hz
  • Power Factor- 1

Maximum Feed Through Current (A)- 2x100

INVERTER

Input Voltage Range (V DC)- 38V - 66V

Output Voltage- 230 VAC ± 2%

Output Frequency- 50Hz ± 0.1%

Cont. Output Power at 25°C³- 15000VA

Cont. Output Power at 25°C- 12000W

Cont. Output Power at 40°C- 10000W

Cont. Output Power at 65°C- 7000W

Peak Power- 25000W

Maximum Efficiency- 96%

Zero Load Power- 110W

Zero Load Power In AES Mode- 75W

Zero Load Power In Search Mode- 20W

CHARGER

Charge Voltage 'Absorption'- 57.6V

Charge Voltage 'Float'- 55.2V

Storage Mode- 52.8V

Charge Current House Battery- 200A

Charge Current Starter Battery- 4A (12V and 24V models only)

Battery Temperature Sensor- Yes

GENERAL

Auxiliary Output- 50A

Programmable Relay- 3x

Protection- a - g

VE.Bus Communication Port- For parallel and three phase operation, remote monitoring and system integration

General Purpose Com. Port- 2x

Remote On/Off- Yes

Operating Temperature- -40°C - 65°C

Humidity (Non-Condensing)- Max 95%

Maximum Altitude- 3500m

ENCLOSURE

Material & Color- Aluminium Blue RAL5012

Protection Category- IP21

Battery-Connection- Four M8 Bolts (2 plus and 2 minus connections)

230V AC-Connection- Bolts M6

Weight- 72lb

Dimensions (HxWxD)- 22.5" x 19.21" x 13.54"

STANDARDS

Safety- EN-IEC 60335-1, EN-IEC 60335-2-29, EN-IEC 62109-1

Emission, Immunity- EN 55014-1, EN 55014-2, EN-IEC 61000-3-2, EN-IEC 61000-3-3, IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3

Road Vehicles- 12V and 24V models- ECE R10-4

Anti-Islanding- See our website

1) Can be adjusted to 60 Hz 120V models available on request

2) Protection Key

A) Output short circuit

B) Overload

C) Battery voltage to high

D) Battery voltage to low

E) Temperature to high

F) 230VAC on inverter output

G) Input voltage ripple to high

3) Non-linear load, crest factor 3:1

4) Up to 25°C ambient

5) Switches off when no external AC source available

6) Programmable relay that can a.o. be set for general alarm, DC under voltage or genset start. stop function

AC Rating- 230V / 4A

DC Rating- 4A up to 35VDC, 1A up to 60VDC