Victron Energy Non-UL Listed 2000VA MutliPlus Inverter/Chargers


The new Victron Energy Multiplus 2000VA is a combined inverter and charger all in one package. It features a true sine wave inverter, adaptive charging, hybrid PowerAssist technology, plus several more integration features. 

Power Control/ Power Assist- Yes

Three Phase and Parallel Operation- Yes

Transfer Switch- 50A

INVERTER

Input Voltage Range-

  • 24/2000/50-50 = 19V - 33V
  • 48/2000/25-50 = 38V - 66V

Output Voltage- 120VAC ± 2%

Output Frequency- 60Hz ± 0.1% (1)

Cont. Output Power at 25°C³- 2000VA

Cont. Output Power at 25°C- 1600W

Cont. Output Power at 40°C- 1400W

Cont. Output Power at 65°C- 1000W

Peak Power- 3500W

Maximum Efficiency-

  • 24/2000/50-50 = 94%
  • 48/2000/25-50 = 95% 

Zero-Load Power-

  • 24/2000/50-50 = 11W
  • 48/2000/25-50 = 11W

Zero-Load Power in Search Mode-

  • 24/2000/50-50 = 4W
  • 48/2000/25-50 = 4W

CHARGER

AC Input Voltage Range- 95VAC - 140VAC

AC Input Frequency- 45Hz - 65Hz

Charge Voltage 'Absorption'-

  • 24/2000/50-50 = 28.8V
  • 48/2000/25-50 = 57.6V

Charge Voltage 'Float"-

  • 24/2000/50-50 = 27.6V
  • 48/2000/25-50 = 55.2V

Storage Mode-

  • 24/2000/50-50 = 26.4V
  • 48/2000/25-50 = 52.8V

Charge Current House Battery-

  • 24/2000/50-50 = 50A
  • 48/2000/25-50 = 25A

Charge Current Starter Battery- 1A (12V and 24V models only)

Battery Temperature Sensor- Yes

GENERAL

Programmable Relay- Yes

Protection- a - g

VE.Bus Communication Port- For parallel and three phase operation, remote monitoring, and system integration

Remote On/Off- On/Off

DIP Switches- Yes (7)

Internal DC Fuse- No

Operating Temperature Range- -40°C - 65°C (fan assisted cooling)

Humidity (Non-condensing)- Max 95%

ENCLOSURE

Material- Steel (RAL 5012)

Protection Category- IP22

Battery-Connection- M8 Bolts

230V AC-Connection- Screw Terminals 13mm² (6AWG)

Weight- 34.17

Dimensions (HxWxD)- 19.92" x 9.29" x 5.78"

STANDARDS

Safety- EN-IEC 60335-1, EN-IEC 60335-2-29, EN 62109-1

Emission Immunity- EN 55014-1, EN 55014-2, EN-IEC 61000-3-2, EN-IEC 61000-3-3, IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3

Automotive Directive- ECE R10-5

1) Can be adjusted to 50Hz

2) Protection:

A) Output short circuit

B) Overload

C) Battery voltage to high

D) Battery voltage to low

E) Temperature to high

F) 230VAC on inverter output

G) Input voltage ripple to high

3) Non-linear load, crest factor 3:1

4) Up to 25°C ambient

5) Programmable relay which can be set for general alarm, DC under voltage or generator start/stop signal function

AC rating- 230V/4A

DC rating- 4A up to 35VDC, 1A up to 60VDC

6) Remote/ Battery charge voltage/ Inverter frequency/ search mode

7) Battery charge voltage/ search mode