The MAGNUM MS2812 Inverter/Charger is designed to meet your most demanding off grid needs. It meets the strict standards of UL458 for mobile use and UL1741 for renewable energy installs. This inverter/charger is Power Factor Corrected (PFC) which means that it uses 25-30% less energy from your generator. Free Shipping in the continental US!
Input Battery Voltage Range- 9 - 16.8VDC
AC Output Voltage Accuracy- 120 VAC ± 5%
Output Frequency And Accuracy- 60Hz ± 0.1Hz
Total Harmonic Distortion- <5%
1 Msec Surge Current- 70
100 Msec Surge Current- 40
5 Second Surge Power- 3900
30 Second Surge Power- 3800
5 Minute Surge Power- 3200
30 Minute Surge Power- 3000
Output Power- 2800
Maximum Continuous Input Current- 373 ADC
Inverter Efficiency- 90%
AC Relay Transfer Time- 16 msecs
Power Consumption - Searching- <8 Watts
Power Consumption - Inverting (no load)- 30 Watts
Output Wave Form- Pure Sin Wave
CHARGER SPECIFICATIONS
Continuous Output At 25°C- 125ADC
Charger Efficiency- 85%
Power Factor- >.95
Input Current For Continuous Rated Output- 18 AAC
GENERAL FEATURES AND CAPABILITIES
Transfer Relay Capability- 30 ACC max. each input (30AC total on MS2000 models, 60 ACC total on all other models)
Five Stage Charging Capability- Bulk, Absorb, Float, Equalize (requires remote) and Battery Saver
Battery Temperature Compensation- Standard with available temp sensor connected (battery temp 0-50°C)
Internal Cooling- 0 to 120 cfm variable speed drive using dual 92mm brushless DC fans
Overcurrent Protection- Yes, with two overlapping circuits
Overtemperature Protection- Yes on transformer, MOSFETS. and battery
Corrosion Protection- Yes, PCB's conformal coated, powder coated chassis/ top, and stainless steel fasteners
Branch-Rated Output Circuit Breakers- Optional on the MS2000 (15 or 20 amp breakers) or MS4048 (20 amp breakers)
Warranty- Three years parts and labor
PHYSICAL SPECIFICATIONS
Dimensions (LxWxH)- 13.75" x 12.65" x 8.0"
Mounting- Shelf or wall (Vents not allowed to face downward unless ME-CB or MMP/MP is installed
Unit Weight- 55lbs
Shipping Weight- 62lbs
Max Operating Altitude- 15,000"
Temperature (Operating/Non-Operating)- -20° - 60°C, -40° - 70°C
Operating Humidity- 0 - 95% RH non-condensing