Our line of ETL listed to UL 48 Volt DC split phase 120/240 Volt AC inverter chargers is the power house for backup, off-grid systems. Built with a 48 Volt DC input, these inverter chargers perform with very little power loss. Users receive a notable increase in efficiency in large systems when compared to using inverters that accept 12 or 24 volts.
INVERTER OUTPUT SPECIFICATIONS
Continuous Output Power- 12,000 Watts
Surge Rating- 36,000 Watts (20 Seconds)
Output Waveform- Pure Sine/ Same and input (Bypass Mode)
100-110-120Vac/ 220-230-240Vac
Nominal Efficiency- >88% (peak)
Line Mode Efficiency- >95%
Output Frequency- 50Hz +/- 0.3Hz/ 60Hz +/- 0.3Hz
Typical Transfer Time- 10ms (Max)
THD- <10% DC
Ambient Operating Temperature- 14°F - 122°F
INPUT SPECIFICATIONS
Nominal Input Voltage- 48.0Vdc
Low Battery Alarm- 42.0Vdc - 44.0Vdc
Low Battery Trip- 40.0Vdc - 42.0Vdc
High Voltage Alarm- 64.0Vdc
Low Battery Voltage Restart- 62.0Vdc
Idle Consumption- 200 Watts
Power Saver Mode Idle Consumption- 40 Watts
Automatic Transfer Switch- 63A @ 220/230/240V
Bypass- 63A @ 220/230/240V
CHARGER SPECIFICATIONS
Output Voltage- Depends on the battery type
Charger Rate- 120A
Four Stage Smart Charger With Current Adjust Dial- 0% - 20% - 100%
DIMENSIONS
Unit Weight- 174lbs
Unit Size (LxWxH)- 23.33" x 16.3" x 7.9"
Shipping Weight- 200lbs
Shipping Size (LxWxH)- 30" x 21.25" x 15.25"